{"id":36224,"date":"2025-10-22T18:35:31","date_gmt":"2025-10-22T10:35:31","guid":{"rendered":"https:\/\/aositerminals.com\/?p=36224"},"modified":"2025-10-23T14:35:27","modified_gmt":"2025-10-23T06:35:27","slug":"how-to-wire-push-in-terminal-block","status":"publish","type":"post","link":"https:\/\/aositerminals.com\/fr\/solutions\/how-to-wire-push-in-terminal-block\/","title":{"rendered":"Comment c\u00e2bler un bloc terminal enfichable : guide \u00e9tape par \u00e9tape"},"content":{"rendered":"<div class=\"aosi-wz-all1\">\n<p>Le c\u00e2blage d'un bloc de jonction \u00e0 insertion directe est un moyen simple et efficace d'\u00e9tablir des connexions \u00e9lectriques s\u00fbres pour vos projets ou syst\u00e8mes d'automatisation. Ce guide vous accompagne \u00e0 chaque \u00e9tape essentielle, de la pr\u00e9paration du fil jusqu'\u00e0 l'obtention de connexions s\u00fbres et fiables. Que vous soyez un passionn\u00e9 de bricolage ou un technicien professionnel, le respect de ces instructions simplifiera vos t\u00e2ches de c\u00e2blage.<\/p>\n\n<h2>Outils et mat\u00e9riaux n\u00e9cessaires<\/h2>\n<p>Avant de commencer, vous devez pr\u00e9parer les outils et mat\u00e9riaux suivants\u00a0:<\/p>\n<ul>\n<li><b>Pince \u00e0 d\u00e9nuder<\/b> \u2013 pour un d\u00e9nudage pr\u00e9cis de l'isolant.<\/li>\n<li><b>Embouts ou fils rigides<\/b> \u2013 n\u00e9cessaires pour une insertion s\u00fbre.<\/li>\n<li><b>Tournevis ou outil \u00e0 levier<\/b> \u2013 n\u00e9cessaire uniquement pour le retrait du fil.<\/li>\n<li><b>Rail DIN (EN 60715)<\/b> \u2013 pour le montage du bloc de jonction.<\/li>\n<li><b>Multim\u00e8tre<\/b> \u2013 pour tester la continuit\u00e9 et la tension apr\u00e8s le c\u00e2blage.<\/li>\n<\/ul>\n<p>\ud83d\udca1 <b>Conseil de pro :<\/b> V\u00e9rifiez toujours la plage de fils sp\u00e9cifi\u00e9e sur le bornier (par ex., 0,5\u20132,5 mm\u00b2) avant le c\u00e2blage afin de garantir des performances de contact optimales.<\/p>\n\n<h2>\u00c9tape 1 \u2013 D\u00e9nuder le fil<\/h2>\n<p>Un d\u00e9nudage correct du fil assure un contact \u00e9lectrique solide et \u00e9vite que les brins de cuivre ne se plient ou ne se cassent.<\/p>\n<ol>\n<li>Utilisez une pince \u00e0 d\u00e9nuder de haute qualit\u00e9 pour retirer environ <b>10\u201311 mm<\/b> d'isolant.<\/li>\n<li>Pour les fils multibrins, sertissez un embout \u00e0 l'extr\u00e9mit\u00e9 pour obtenir une surface cylindrique lisse.<\/li>\n<li>Assurez-vous qu'aucun cuivre nu ne reste expos\u00e9 \u00e0 l'ext\u00e9rieur de l'entr\u00e9e du bornier.<\/li>\n<\/ol>\n\n<div class=\"aosi-wz-img1\" style=\"margin-bottom:40px;\"><img decoding=\"async\" src=\"https:\/\/aositerminals.com\/wp-content\/uploads\/2025\/10\/strip-wire-for-push-in-terminal-block-connection.png\" alt=\"d\u00e9nuder le fil pour la connexion au bornier \u00e0 insertion directe\" \/><\/div>\n\n<h2>\u00c9tape 2 \u2013 Ins\u00e9rer dans la borne \u00e0 insertion directe<\/h2>\n<p>C'est le principal avantage de la technologie \u00e0 insertion directe \u2014 une insertion rapide et sans outil.<\/p>\n<ol>\n<li>Poussez simplement le fil pr\u00e9par\u00e9 directement dans l'orifice d'entr\u00e9e du conducteur.<\/li>\n<li>La <b>borne \u00e0 ressort en acier inoxydable<\/b> interne saisira automatiquement le conducteur fermement.<\/li>\n<li>Aucun tournevis ni r\u00e9glage de couple n'est n\u00e9cessaire.<\/li>\n<li>Une fois ins\u00e9r\u00e9, tirez l\u00e9g\u00e8rement sur le fil pour confirmer qu'il est bien fix\u00e9.<\/li>\n<\/ol>\n<p>La connexion \u00e0 insertion directe permet d'\u00e9conomiser jusqu'\u00e0 <b>70\u00a0% du temps de c\u00e2blage<\/b> par rapport aux connexions \u00e0 vis traditionnelles.<\/p>\n<p>\ud83d\udd17 Pour une explication d\u00e9taill\u00e9e du m\u00e9canisme, voir <a href=\"https:\/\/aositerminals.com\/fr\/solutions\/push-in-connection-technology\/\">Technologie de connexion \u00e0 insertion directe dans les blocs de jonction<\/a><\/p>\n\n<div class=\"aosi-wz-cpkp0724\" style=\"margin-bottom:40px;\">\n    <div class=\"aosi-wz-cpkp0724-left\">\n      <img decoding=\"async\" src=\"https:\/\/aositerminals.com\/wp-content\/uploads\/2025\/10\/banner-din-rail-terminal-block.png\" alt=\"Blocs de jonction \u00e0 rail DIN \u00e0 insertion directe\">\n    <\/div>\n    <div class=\"aosi-wz-cpkp0724-right\">\n      <div>\n      <span id=\"elementor-toc__heading-anchor-1\" class=\"elementor-menu-anchor\"><\/span><h4>Blocs de jonction \u00e0 rail DIN \u00e0 insertion directe<\/h4>\n      <ul>\n        <li>Connexion \u00e0 insertion directe sans outil, gain de temps de c\u00e2blage<\/li>\n        <li>Options multi-niveaux (2\u00a0niveaux\/3\u00a0niveaux) pour armoires compactes<\/li>\n        <li>2,5\u20136 mm\u00b2 \/ 24V\u2013600V \/ traversant &#038; mise \u00e0 la terre<\/li>\n        <li>Mod\u00e8les \u00e9quivalents Phoenix\/Weidm\u00fcller disponibles<\/li>\n      <\/ul>\n      <a class=\"aosi-wz-cpkp0724-right-btn\" href=\"https:\/\/aositerminals.com\/fr\/product-category\/din-rail-terminal-block\/push-in-din-rail-terminal-block\/\">En savoir plus<\/a>\n    <\/div>\n    <\/div>\n<\/div>\n\n<h2>\u00c9tape 3 \u2013 V\u00e9rifier la connexion &#038; test de traction<\/h2>\n<p>Apr\u00e8s avoir ins\u00e9r\u00e9 tous les conducteurs\u00a0:<\/p>\n<ol>\n<li>Effectuez un <b>test de traction l\u00e9ger<\/b> sur chaque fil pour garantir un verrouillage correct.<\/li>\n<li>Utilisez un <b>multim\u00e8tre<\/b> pour v\u00e9rifier la continuit\u00e9 entre les points d'entr\u00e9e et de sortie.<\/li>\n<li>V\u00e9rifiez que les fils sont align\u00e9s dans la m\u00eame direction \u2014 un cheminement coh\u00e9rent am\u00e9liore l'inspection visuelle et la s\u00e9curit\u00e9.<\/li>\n<\/ol>\n<p>Cette \u00e9tape de v\u00e9rification est essentielle avant la mise sous tension du syst\u00e8me, en particulier pour les blocs de jonction multicouches ou \u00e0 haute densit\u00e9 utilis\u00e9s dans les armoires de commande d'automates.<\/p>\n\n<h2>\u00c9tape 4 \u2013 Lib\u00e9rer le fil (bouton ou levier)<\/h2>\n<p>Le retrait d'un fil d'un bloc de jonction \u00e0 insertion directe est tout aussi simple.<\/p>\n<ol>\n<li>Rep\u00e9rez le <b>bouton ou levier de lib\u00e9ration orange<\/b> sur le bornier.<\/li>\n<li>Appuyez d\u00e9licatement \u00e0 l'aide d'un tournevis plat ou du doigt.<\/li>\n<li>Tout en appuyant, retirez le fil en le tirant bien droit pour \u00e9viter de plier ou d'endommager la pince.<\/li>\n<\/ol>\n<p>Certains mod\u00e8les disposent de m\u00e9canismes \u00e0 levier qui rendent ce processus encore plus rapide, id\u00e9al pour les maintenances fr\u00e9quentes dans les syst\u00e8mes d'automatisation.<\/p>\n\n<h2>Conseils de s\u00e9curit\u00e9 et de maintenance<\/h2>\n<p>Un c\u00e2blage correct garantit une fiabilit\u00e9 \u00e0 long terme et pr\u00e9vient la surchauffe ou les courts-circuits. Suivez ces bonnes pratiques :<\/p>\n<ul>\n<li>V\u00e9rifiez toujours la section du conducteur et la classe d'isolation.<\/li>\n<li>\u00c9vitez d'ins\u00e9rer directement des fils \u00e9tam\u00e9s ou oxyd\u00e9s.<\/li>\n<li>Maintenez un \u00e9tiquetage clair pour chaque point de borne.<\/li>\n<li>Gardez l'armoire propre et exempte de poussi\u00e8re pour \u00e9viter l'oxydation des contacts.<\/li>\n<li>Rev\u00e9rifiez p\u00e9riodiquement les connexions lors de la maintenance de l'\u00e9quipement.<\/li>\n<\/ul>\n<p>Avec ces pr\u00e9cautions, les bornes \u00e0 insertion directe peuvent fonctionner en toute s\u00e9curit\u00e9 pendant plus de 10 ans sans n\u00e9cessiter de resserrage \u2014 une raison essentielle de leur pr\u00e9f\u00e9rence dans l'automatisation industrielle moderne.<\/p>\n\n<h2>FAQ \u2013 Comment c\u00e2bler un bornier \u00e0 insertion directe<\/h2>\n<div class=\"aosi-wz-sfqall0723\">\n<button class=\"aosi-wz-sfq0723\">Q1 : Comment fonctionnent les borniers \u00e0 insertion directe ?<\/button>\n<div class=\"aosi-wz-sfq0723-lb\">\n  <p>R1 : Les borniers \u00e0 insertion directe utilisent un <b>m\u00e9canisme de pince \u00e0 ressort<\/b> qui saisit automatiquement le conducteur lors de l'insertion. Le ressort interne en acier inoxydable maintient une pression de contact constante sur le fil, assurant une connexion \u00e9tanche aux gaz et r\u00e9sistante aux vibrations. Cela \u00e9limine le besoin de vis ou d'outils de couple et permet un c\u00e2blage plus rapide.<\/p>\n<\/div>\n\n<button class=\"aosi-wz-sfq0723\">Q2 : Quelle est la longueur de d\u00e9nudage correcte pour les bornes \u00e0 insertion directe ?<\/button>\n<div class=\"aosi-wz-sfq0723-lb\">\n  <p>R2 : La plupart des bornes \u00e0 insertion directe n\u00e9cessitent de d\u00e9nuder l'isolation sur <b>10\u201311 mm (0.4 in)<\/b> avant l'insertion. Cette longueur assure un contact complet avec le ressort tout en \u00e9vitant le cuivre \u00e0 nu. V\u00e9rifiez toujours la longueur de d\u00e9nudage exacte sp\u00e9cifi\u00e9e dans la fiche technique du fabricant.<\/p>\n<\/div>\n\n<button class=\"aosi-wz-sfq0723\">Q3 : Dois-je utiliser des embouts pour les connexions \u00e0 insertion directe ?<\/button>\n<div class=\"aosi-wz-sfq0723-lb\">\n  <p>R3 : Pour les fils multibrins, l'utilisation d'embouts est recommand\u00e9e car ils compriment les brins libres et assurent un contact constant. Pour les fils rigides, les embouts ne sont pas n\u00e9cessaires \u2014 le conducteur peut \u00eatre ins\u00e9r\u00e9 directement. Cette recommandation est conforme aux normes de c\u00e2blage IEC 60352-7 et UL 1059.<\/p>\n<\/div>\n\n<button class=\"aosi-wz-sfq0723\">Q4 : Comment retirer un fil d'un bornier \u00e0 insertion directe ?<\/button>\n<div class=\"aosi-wz-sfq0723-lb\">\n  <p>R4 : La plupart des bornes \u00e0 insertion directe disposent d'un <b>bouton de d\u00e9verrouillage orange ou gris<\/b>. Appuyez sur ce bouton avec un tournevis ou le bout du doigt tout en tirant doucement le fil bien droit. Cela lib\u00e8re la pince \u00e0 ressort en toute s\u00e9curit\u00e9 sans endommager le conducteur.<\/p>\n<\/div>\n\n<button class=\"aosi-wz-sfq0723\">Q5 : Les bornes \u00e0 insertion directe peuvent-elles supporter des circuits \u00e0 courant \u00e9lev\u00e9 ou de puissance ?<\/button>\n<div class=\"aosi-wz-sfq0723-lb\">\n  <p>R5 : Oui. Les bornes \u00e0 insertion directe de qualit\u00e9 industrielle sont con\u00e7ues pour supporter jusqu'\u00e0 <b>57 A<\/b> selon le pas et la section du conducteur. Par exemple, les mod\u00e8les PT6 et PT10 d'AOSI conviennent aux circuits de puissance et sont conformes aux <b>IEC 60947-7-1<\/b> exigences de capacit\u00e9 de transport de courant.<\/p>\n<\/div>\n\n<button class=\"aosi-wz-sfq0723\">Q6 : Quels sont les avantages de s\u00e9curit\u00e9 des bornes \u00e0 insertion directe par rapport aux bornes \u00e0 vis ?<\/button>\n<div class=\"aosi-wz-sfq0723-lb\">\n  <p>R6 : Les bornes \u00e0 insertion directe offrent une force de serrage constante, \u00e9liminant le risque de desserrage des vis sous l'effet des vibrations ou des cycles thermiques. Elles sont sans entretien, plus rapides \u00e0 c\u00e2bler et r\u00e9duisent les erreurs d'installation de 50 \u00e0 70 %. Elles sont donc plus s\u00fbres pour les armoires de commande industrielles, les syst\u00e8mes PLC et l'automatisation du b\u00e2timent.<\/p>\n<\/div>\n<\/div>\n\n<h2>Conclusion<\/h2>\n<p>Les borniers \u00e0 insertion directe ont transform\u00e9 les pratiques de c\u00e2blage dans les applications industrielles et de bricolage. En suivant ces \u00e9tapes simples \u2014 d\u00e9nuder, ins\u00e9rer, tester et lib\u00e9rer \u2014 vous obtenez des connexions fiables et sans entretien en quelques minutes.<\/p>\n<p>Pour des solutions certifi\u00e9es, directes d'usine, alliant rapidit\u00e9 et s\u00e9curit\u00e9, d\u00e9couvrez la <a href=\"https:\/\/aositerminals.com\/fr\/product-category\/din-rail-terminal-block\/push-in-din-rail-terminal-block\/\">S\u00e9rie de borniers \u00e0 insertion directe<\/a> con\u00e7ue pour les syst\u00e8mes PLC, de puissance et d'automatisation.<\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"Apprenez \u00e0 c\u00e2bler un bloc de jonction \u00e0 insertion directe \u00e9tape par \u00e9tape \u2014 des connexions rapides, sans outil et fiables pour les armoires d'automates et les syst\u00e8mes d'automatisation.","protected":false},"author":4,"featured_media":36226,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[1],"tags":[],"class_list":["post-36224","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-uncategorized"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v24.7 (Yoast SEO v24.7) - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>How to Wire Push-in Terminal Block: Step-by-Step Guide - AOSI Terminal Blocks &amp; Module Manufacturer | Industrial Connectivity Solutions<\/title>\n<meta name=\"description\" content=\"Learn how to wire a push-in terminal block step by step \u2014 fast, tool-free, and reliable connections for PLC panels and automation systems.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/aositerminals.com\/fr\/solutions\/how-to-wire-push-in-terminal-block\/\" \/>\n<meta property=\"og:locale\" content=\"fr_FR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"How to Wire Push-in Terminal Block: Step-by-Step Guide\" \/>\n<meta property=\"og:description\" content=\"Learn how to wire a push-in terminal block step by step \u2014 fast, tool-free, and reliable connections for PLC panels and automation systems.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/aositerminals.com\/fr\/solutions\/how-to-wire-push-in-terminal-block\/\" \/>\n<meta property=\"og:site_name\" content=\"AOSI Terminal Blocks &amp; Module Manufacturer | Industrial Connectivity Solutions\" \/>\n<meta property=\"article:published_time\" content=\"2025-10-22T10:35:31+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-10-23T06:35:27+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/aositerminals.com\/wp-content\/uploads\/2025\/10\/How-to-Wire-Push-in-Terminal-Block-Step-by-Step-Guide.png\" \/>\n\t<meta property=\"og:image:width\" content=\"800\" \/>\n\t<meta property=\"og:image:height\" content=\"600\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"liqi001\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u00c9crit par\" \/>\n\t<meta name=\"twitter:data1\" content=\"liqi001\" \/>\n\t<meta name=\"twitter:label2\" content=\"Dur\u00e9e de lecture estim\u00e9e\" \/>\n\t<meta name=\"twitter:data2\" content=\"5 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/aositerminals.com\/fr\/solutions\/how-to-wire-push-in-terminal-block\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/aositerminals.com\/fr\/solutions\/how-to-wire-push-in-terminal-block\/\"},\"author\":{\"name\":\"liqi001\",\"@id\":\"https:\/\/aositerminals.com\/ru\/#\/schema\/person\/ea80420f2fbb21490fba5efdc31bc514\"},\"headline\":\"How to Wire Push-in Terminal Block: Step-by-Step Guide\",\"datePublished\":\"2025-10-22T10:35:31+00:00\",\"dateModified\":\"2025-10-23T06:35:27+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/aositerminals.com\/fr\/solutions\/how-to-wire-push-in-terminal-block\/\"},\"wordCount\":905,\"publisher\":{\"@id\":\"https:\/\/aositerminals.com\/ru\/#organization\"},\"image\":{\"@id\":\"https:\/\/aositerminals.com\/fr\/solutions\/how-to-wire-push-in-terminal-block\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/aositerminals.com\/wp-content\/uploads\/2025\/10\/How-to-Wire-Push-in-Terminal-Block-Step-by-Step-Guide.png\",\"articleSection\":[\"\u672a\u5206\u7c7b\"],\"inLanguage\":\"fr-FR\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/aositerminals.com\/fr\/solutions\/how-to-wire-push-in-terminal-block\/\",\"url\":\"https:\/\/aositerminals.com\/fr\/solutions\/how-to-wire-push-in-terminal-block\/\",\"name\":\"How to Wire Push-in Terminal Block: Step-by-Step Guide - AOSI Terminal Blocks &amp; Module Manufacturer | Industrial Connectivity Solutions\",\"isPartOf\":{\"@id\":\"https:\/\/aositerminals.com\/ru\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/aositerminals.com\/fr\/solutions\/how-to-wire-push-in-terminal-block\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/aositerminals.com\/fr\/solutions\/how-to-wire-push-in-terminal-block\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/aositerminals.com\/wp-content\/uploads\/2025\/10\/How-to-Wire-Push-in-Terminal-Block-Step-by-Step-Guide.png\",\"datePublished\":\"2025-10-22T10:35:31+00:00\",\"dateModified\":\"2025-10-23T06:35:27+00:00\",\"description\":\"Learn how to wire a push-in terminal block step by step \u2014 fast, tool-free, and reliable connections for PLC panels and automation systems.\",\"breadcrumb\":{\"@id\":\"https:\/\/aositerminals.com\/fr\/solutions\/how-to-wire-push-in-terminal-block\/#breadcrumb\"},\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/aositerminals.com\/fr\/solutions\/how-to-wire-push-in-terminal-block\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\/\/aositerminals.com\/fr\/solutions\/how-to-wire-push-in-terminal-block\/#primaryimage\",\"url\":\"https:\/\/aositerminals.com\/wp-content\/uploads\/2025\/10\/How-to-Wire-Push-in-Terminal-Block-Step-by-Step-Guide.png\",\"contentUrl\":\"https:\/\/aositerminals.com\/wp-content\/uploads\/2025\/10\/How-to-Wire-Push-in-Terminal-Block-Step-by-Step-Guide.png\",\"width\":800,\"height\":600,\"caption\":\"how to wire push-in terminal block\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/aositerminals.com\/fr\/solutions\/how-to-wire-push-in-terminal-block\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"\u9996\u9875\",\"item\":\"https:\/\/aositerminals.com\/en\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"How to Wire Push-in Terminal Block: Step-by-Step Guide\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/aositerminals.com\/ru\/#website\",\"url\":\"https:\/\/aositerminals.com\/ru\/\",\"name\":\"Industrial Automation Terminal Blocks\",\"description\":\"Factory-direct pluggable, spring &amp; screw terminal blocks and I\/O \/ relay modules. Fast OEM \/ ODM, global shipping.\",\"publisher\":{\"@id\":\"https:\/\/aositerminals.com\/ru\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/aositerminals.com\/ru\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"fr-FR\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/aositerminals.com\/ru\/#organization\",\"name\":\"Industrial Automation Terminal Blocks\",\"url\":\"https:\/\/aositerminals.com\/ru\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\/\/aositerminals.com\/ru\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/aositerminals.com\/wp-content\/uploads\/2025\/03\/aff0c45cf8d34c8eee2824ecf650eb5.webp\",\"contentUrl\":\"https:\/\/aositerminals.com\/wp-content\/uploads\/2025\/03\/aff0c45cf8d34c8eee2824ecf650eb5.webp\",\"width\":215,\"height\":97,\"caption\":\"Industrial Automation Terminal Blocks\"},\"image\":{\"@id\":\"https:\/\/aositerminals.com\/ru\/#\/schema\/logo\/image\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\/\/aositerminals.com\/ru\/#\/schema\/person\/ea80420f2fbb21490fba5efdc31bc514\",\"name\":\"liqi001\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\/\/aositerminals.com\/ru\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/c3bff73b203e4695c70f815f58d8fc65bdd703d79bdd517e01042fd8bee47f1e?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/c3bff73b203e4695c70f815f58d8fc65bdd703d79bdd517e01042fd8bee47f1e?s=96&d=mm&r=g\",\"caption\":\"liqi001\"},\"url\":\"https:\/\/aositerminals.com\/fr\/solutions\/author\/liqi001\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Comment c\u00e2bler un bloc de jonction push-in : guide \u00e9tape par \u00e9tape - Fabricant de blocs terminaux et modules AOSI | Solutions de connectivit\u00e9 industrielle","description":"Apprenez \u00e0 c\u00e2bler un bloc de jonction \u00e0 insertion directe \u00e9tape par \u00e9tape \u2014 des connexions rapides, sans outil et fiables pour les armoires d'automates et les syst\u00e8mes d'automatisation.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/aositerminals.com\/fr\/solutions\/how-to-wire-push-in-terminal-block\/","og_locale":"fr_FR","og_type":"article","og_title":"How to Wire Push-in Terminal Block: Step-by-Step Guide","og_description":"Learn how to wire a push-in terminal block step by step \u2014 fast, tool-free, and reliable connections for PLC panels and automation systems.","og_url":"https:\/\/aositerminals.com\/fr\/solutions\/how-to-wire-push-in-terminal-block\/","og_site_name":"AOSI Terminal Blocks &amp; Module Manufacturer | Industrial Connectivity Solutions","article_published_time":"2025-10-22T10:35:31+00:00","article_modified_time":"2025-10-23T06:35:27+00:00","og_image":[{"width":800,"height":600,"url":"https:\/\/aositerminals.com\/wp-content\/uploads\/2025\/10\/How-to-Wire-Push-in-Terminal-Block-Step-by-Step-Guide.png","type":"image\/png"}],"author":"liqi001","twitter_card":"summary_large_image","twitter_misc":{"\u00c9crit par":"liqi001","Dur\u00e9e de lecture estim\u00e9e":"5 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/aositerminals.com\/fr\/solutions\/how-to-wire-push-in-terminal-block\/#article","isPartOf":{"@id":"https:\/\/aositerminals.com\/fr\/solutions\/how-to-wire-push-in-terminal-block\/"},"author":{"name":"liqi001","@id":"https:\/\/aositerminals.com\/ru\/#\/schema\/person\/ea80420f2fbb21490fba5efdc31bc514"},"headline":"How to Wire Push-in Terminal Block: Step-by-Step Guide","datePublished":"2025-10-22T10:35:31+00:00","dateModified":"2025-10-23T06:35:27+00:00","mainEntityOfPage":{"@id":"https:\/\/aositerminals.com\/fr\/solutions\/how-to-wire-push-in-terminal-block\/"},"wordCount":905,"publisher":{"@id":"https:\/\/aositerminals.com\/ru\/#organization"},"image":{"@id":"https:\/\/aositerminals.com\/fr\/solutions\/how-to-wire-push-in-terminal-block\/#primaryimage"},"thumbnailUrl":"https:\/\/aositerminals.com\/wp-content\/uploads\/2025\/10\/How-to-Wire-Push-in-Terminal-Block-Step-by-Step-Guide.png","articleSection":["\u672a\u5206\u7c7b"],"inLanguage":"fr-FR"},{"@type":"WebPage","@id":"https:\/\/aositerminals.com\/fr\/solutions\/how-to-wire-push-in-terminal-block\/","url":"https:\/\/aositerminals.com\/fr\/solutions\/how-to-wire-push-in-terminal-block\/","name":"Comment c\u00e2bler un bloc de jonction push-in : guide \u00e9tape par \u00e9tape - Fabricant de blocs terminaux et modules AOSI | Solutions de connectivit\u00e9 industrielle","isPartOf":{"@id":"https:\/\/aositerminals.com\/ru\/#website"},"primaryImageOfPage":{"@id":"https:\/\/aositerminals.com\/fr\/solutions\/how-to-wire-push-in-terminal-block\/#primaryimage"},"image":{"@id":"https:\/\/aositerminals.com\/fr\/solutions\/how-to-wire-push-in-terminal-block\/#primaryimage"},"thumbnailUrl":"https:\/\/aositerminals.com\/wp-content\/uploads\/2025\/10\/How-to-Wire-Push-in-Terminal-Block-Step-by-Step-Guide.png","datePublished":"2025-10-22T10:35:31+00:00","dateModified":"2025-10-23T06:35:27+00:00","description":"Apprenez \u00e0 c\u00e2bler un bloc de jonction \u00e0 insertion directe \u00e9tape par \u00e9tape \u2014 des connexions rapides, sans outil et fiables pour les armoires d'automates et les syst\u00e8mes d'automatisation.","breadcrumb":{"@id":"https:\/\/aositerminals.com\/fr\/solutions\/how-to-wire-push-in-terminal-block\/#breadcrumb"},"inLanguage":"fr-FR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/aositerminals.com\/fr\/solutions\/how-to-wire-push-in-terminal-block\/"]}]},{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/aositerminals.com\/fr\/solutions\/how-to-wire-push-in-terminal-block\/#primaryimage","url":"https:\/\/aositerminals.com\/wp-content\/uploads\/2025\/10\/How-to-Wire-Push-in-Terminal-Block-Step-by-Step-Guide.png","contentUrl":"https:\/\/aositerminals.com\/wp-content\/uploads\/2025\/10\/How-to-Wire-Push-in-Terminal-Block-Step-by-Step-Guide.png","width":800,"height":600,"caption":"how to wire push-in terminal block"},{"@type":"BreadcrumbList","@id":"https:\/\/aositerminals.com\/fr\/solutions\/how-to-wire-push-in-terminal-block\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"\u9996\u9875","item":"https:\/\/aositerminals.com\/en\/"},{"@type":"ListItem","position":2,"name":"How to Wire Push-in Terminal Block: Step-by-Step Guide"}]},{"@type":"WebSite","@id":"https:\/\/aositerminals.com\/ru\/#website","url":"https:\/\/aositerminals.com\/ru\/","name":"Bornes d'automatisation industrielle","description":"Blocs de bornes enfichables, \u00e0 ressort et \u00e0 vis et modules d'E\/S\/de relais. OEM \/ ODM rapide, exp\u00e9dition mondiale.","publisher":{"@id":"https:\/\/aositerminals.com\/ru\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/aositerminals.com\/ru\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"fr-FR"},{"@type":"Organization","@id":"https:\/\/aositerminals.com\/ru\/#organization","name":"Bornes d'automatisation industrielle","url":"https:\/\/aositerminals.com\/ru\/","logo":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/aositerminals.com\/ru\/#\/schema\/logo\/image\/","url":"https:\/\/aositerminals.com\/wp-content\/uploads\/2025\/03\/aff0c45cf8d34c8eee2824ecf650eb5.webp","contentUrl":"https:\/\/aositerminals.com\/wp-content\/uploads\/2025\/03\/aff0c45cf8d34c8eee2824ecf650eb5.webp","width":215,"height":97,"caption":"Industrial Automation Terminal Blocks"},"image":{"@id":"https:\/\/aositerminals.com\/ru\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/aositerminals.com\/ru\/#\/schema\/person\/ea80420f2fbb21490fba5efdc31bc514","name":"liqi001","image":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/aositerminals.com\/ru\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/c3bff73b203e4695c70f815f58d8fc65bdd703d79bdd517e01042fd8bee47f1e?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/c3bff73b203e4695c70f815f58d8fc65bdd703d79bdd517e01042fd8bee47f1e?s=96&d=mm&r=g","caption":"liqi001"},"url":"https:\/\/aositerminals.com\/fr\/solutions\/author\/liqi001\/"}]}},"_links":{"self":[{"href":"https:\/\/aositerminals.com\/fr\/wp-json\/wp\/v2\/posts\/36224","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/aositerminals.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/aositerminals.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/aositerminals.com\/fr\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/aositerminals.com\/fr\/wp-json\/wp\/v2\/comments?post=36224"}],"version-history":[{"count":3,"href":"https:\/\/aositerminals.com\/fr\/wp-json\/wp\/v2\/posts\/36224\/revisions"}],"predecessor-version":[{"id":36299,"href":"https:\/\/aositerminals.com\/fr\/wp-json\/wp\/v2\/posts\/36224\/revisions\/36299"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/aositerminals.com\/fr\/wp-json\/wp\/v2\/media\/36226"}],"wp:attachment":[{"href":"https:\/\/aositerminals.com\/fr\/wp-json\/wp\/v2\/media?parent=36224"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/aositerminals.com\/fr\/wp-json\/wp\/v2\/categories?post=36224"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/aositerminals.com\/fr\/wp-json\/wp\/v2\/tags?post=36224"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}