{"id":36878,"date":"2025-11-03T09:48:26","date_gmt":"2025-11-03T01:48:26","guid":{"rendered":"https:\/\/aositerminals.com\/?p=36878"},"modified":"2025-11-03T15:47:41","modified_gmt":"2025-11-03T07:47:41","slug":"unstable-encoder-signal-in-plc","status":"publish","type":"post","link":"https:\/\/aositerminals.com\/it\/solutions\/unstable-encoder-signal-in-plc\/","title":{"rendered":"Perch\u00e9 i segnali dell'encoder diventano instabili nei sistemi PLC (e come risolverlo)"},"content":{"rendered":"<div class=\"aosi-wz-all1\">\n<p>Nella moderna automazione industriale, <strong>il feedback dell'encoder<\/strong> \u00e8 il battito del controllo di precisione: determina velocit\u00e0, posizione e sincronizzazione del motore. Eppure gli ingegneri si trovano spesso ad affrontare un problema frustrante: il segnale dell'encoder diventa instabile quando viene collegato a un PLC. Gli impulsi fluttuano, i valori derivano e le macchine perdono precisione.<\/p>\n<p>Questo articolo spiega le principali cause dei <strong>segnali instabili dell'encoder<\/strong>, come si verifica l'interferenza e i modi pi\u00f9 efficaci per stabilizzare il feedback degli impulsi utilizzando moduli di isolamento e distribuzione.<\/p>\n\n<div class=\"aosi-wz-img1\" style=\"margin-bottom: 40px;\"><img decoding=\"async\" src=\"https:\/\/aositerminals.com\/wp-content\/uploads\/2025\/10\/unstable-encoder-signals.avif\" alt=\"segnali instabili dell&#039;encoder\" \/><\/div>\n\n<h2>Cause comuni dei segnali instabili dell'encoder<\/h2>\n<p>L'instabilit\u00e0 dell'encoder \u00e8 solitamente causata da <b>rumore elettrico<\/b>, <b>anelli di terra<\/b>, o <b>degrado del segnale<\/b>.<br>Quando i cavi dell'encoder passano vicino a linee di potenza o inverter (VFD), l'interferenza elettromagnetica (EMI) distorce gli impulsi A\/B\/Z. Anche le differenze di potenziale di terra tra l'encoder e il PLC possono causare <b>perdita di conteggio o impulsi duplicati<\/b>.<\/p>\n<p>Nella maggior parte dei sistemi, i segnali instabili possono essere mitigati utilizzando uscite differenziali RS422 o aggiungendo moduli di isolamento. Consultate il nostro articolo <a href=\"https:\/\/aositerminals.com\/it\/solutions\/rs422-vs-ttl-encoder-signals\/\">Segnali encoder RS422 e TTL: quale \u00e8 migliore per il vostro sistema di automazione<\/a> per un confronto pi\u00f9 approfondito.<\/p>\n\n<div class=\"aosi-wz-table2\" style=\"margin-bottom: 40px;\">\n<table class=\"aosi-wz-table1\">\n<tbody>\n<tr>\n<td>\n<b>Causa<\/b>\n<\/td>\n<td>\n<b>Effetto<\/b>\n<\/td>\n<td>\n<b>Suggerimento diagnostico<\/b>\n<\/td>\n<\/tr>\n<tr>\n<td>EMI<\/td>\n<td>Picchi di segnale casuali, impulsi mancanti o in eccesso<\/td>\n<td>Confrontate il rumore dell'encoder con l'accensione\/spegnimento della macchina<\/td>\n<\/tr>\n<tr>\n<td>Anelli di terra<\/td>\n<td>Picchi intermittenti, riferimento di segnale fluttuante<\/td>\n<td>Verificare le differenze di potenziale di terra<\/td>\n<\/tr>\n<tr>\n<td>Schermatura insufficiente<\/td>\n<td>Rumore\/ronzio sul segnale, in aumento con la lunghezza del cavo<\/td>\n<td>Ispezionare la continuit\u00e0 della schermatura e il percorso dei cavi<\/td>\n<\/tr>\n<tr>\n<td>Vibrazioni meccaniche<\/td>\n<td>Interruzioni, falsi trigger, deriva del segnale<\/td>\n<td>Osservare la risposta durante il movimento della macchina<\/td>\n<\/tr>\n<tr>\n<td>Problemi di qualit\u00e0 del cavo<\/td>\n<td>Impulsi irregolari, perdita totale<\/td>\n<td>Provare un cavo patch corto per il test<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n\n<h2>Come il rumore elettrico influisce sulla precisione del PLC<\/h2>\n<p>Il rumore elettrico \u00e8 il killer silenzioso della precisione del PLC. La distorsione degli impulsi, causata dall'accoppiamento con la linea di alimentazione, da carichi induttivi o da capacit\u00e0 parassite, porta il PLC a rilevare impulsi \u201cfantasma\u201d o a perdere del tutto le transizioni reali. Nel controllo di posizione e velocit\u00e0, ci\u00f2 si traduce in passi saltati, feedback oscillante o ritardo dell'asse.<\/p>\n<p>Il \u201cfiltro antirumore per encoder\u201d \u00e8 una difesa essenziale. Ne esistono due tipi:<\/p>\n<ul>\n<li>Filtri antirumore hardware: circuiti fisici che bloccano le frequenze indesiderate all'ingresso del segnale. Gestiscono direttamente le interferenze ad alta frequenza e offrono una protezione robusta, soprattutto se posizionati vicino alla sorgente.<\/li>\n<li>Filtraggio software: gli algoritmi lato PLC tentano di ignorare le variazioni di segnale troppo rapide o incoerenti per essere impulsi reali. Funziona bene per piccoli disturbi, ma non pu\u00f2 fermare forti interferenze a livello hardware.<\/li>\n<\/ul>\n<p><b>Filtraggio antirumore dell'encoder: hardware vs. software<\/b><\/p>\n\n<div class=\"aosi-wz-table2\">\n<table class=\"aosi-wz-table1\">\n<tbody>\n<tr>\n<td>\n<b>Filtraggio<\/b>\n<\/td>\n<td>\n<b>Come funziona<\/b>\n<\/td>\n<td>\n<b>Pro<\/b>\n<\/td>\n<td>\n<b>Contro<\/b>\n<\/td>\n<\/tr>\n<tr>\n<td>Filtro hardware<\/td>\n<td>Blocca le EMI sul circuito di ingresso<\/td>\n<td>Veloce, efficace<\/td>\n<td>Deve essere installato<\/td>\n<\/tr>\n<tr>\n<td>Filtro software<\/td>\n<td>La logica del PLC esegue il debounce degli impulsi<\/td>\n<td>Semplice da regolare<\/td>\n<td>Pu\u00f2 aggiungere latenza, limitato contro forti EMI<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n\n<p>Per ulteriori consigli sulla distribuzione sicura dei segnali dell'encoder, vedere: <a href=\"https:\/\/aositerminals.com\/it\/solutions\/split-encoder-signal-to-multiple-devices\/\">Come dividere in sicurezza un segnale encoder su pi\u00f9 dispositivi?<\/a><\/p>\n<p>Il rumore proviene anche dai servoazionamenti o dalle commutazioni dei rel\u00e8 vicini, che inducono tensioni transitorie.<\/p>\n<p>Nei sistemi di confezionamento o nei trasportatori, questi errori causano spesso stampe fuori registro, etichette disallineate o prelievi robotici falliti.<\/p>\n\n<h2>Il ruolo dei moduli di isolamento e distribuzione degli impulsi<\/h2>\n<p>Un <strong>modulo di distribuzione degli impulsi dell'encoder<\/strong> funge da interfaccia protettiva tra encoder e PLC. Filtra il rumore e rigenera il segnale tramite isolamento ottico e driver RS422.<\/p>\n\n<div class=\"aosi-wz-img1\"><img decoding=\"async\" src=\"https:\/\/aositerminals.com\/wp-content\/uploads\/2025\/10\/encoder-isolation-module-wiring-diagram.jpg\" alt=\"schema di cablaggio del modulo di isolamento dell&#039;encoder\" \/><\/div>\n\n<p><b>In che modo aiutano?<\/b><\/p>\n<ul>\n<li>Isolamento: utilizzando optoisolatori, interrompono qualsiasi percorso diretto verso terra, eliminando potenziali anelli di massa.<\/li>\n<li>Uscita differenziale: RS422 e standard simili inviano gli impulsi su due fili; conta solo la differenza di tensione, rendendoli altamente immuni al rumore di modo comune e alle interferenze dei cavi.<\/li>\n<\/ul>\n\n<div class=\"aosi-wz-cpkp0724\">\n    <div class=\"aosi-wz-cpkp0724-left\">\n      <img decoding=\"async\" src=\"https:\/\/aositerminals.com\/wp-content\/uploads\/2025\/10\/Encoder-Pulse-Distribution-Module.png\" alt=\"Modulo di distribuzione degli impulsi AOSI EJ-XABZ\">\n    <\/div>\n    <div class=\"aosi-wz-cpkp0724-right\">\n      <div>\n      <span id=\"elementor-toc__heading-anchor-1\" class=\"elementor-menu-anchor\"><\/span><h4>Codice modello: modulo di distribuzione degli impulsi AOSI EJ-XABZ<\/h4>\n      <ul style=\"list-style-type:none;padding-left:0px\">\n        <li>Il modulo di distribuzione degli impulsi dell'encoder differenziale RS422 AOSI fornisce pi\u00f9 uscite isolate per una trasmissione del segnale ABZ pulita e stabile. \u00c8 progettato per il feedback ad alta velocit\u00e0 del PLC, la sincronizzazione dei servoazionamenti e i sistemi di automazione che richiedono una distribuzione del segnale priva di rumore.<\/li>\n      <\/ul>\n      <a class=\"aosi-wz-cpkp0724-right-btn\" href=\"https:\/\/aositerminals.com\/it\/product-category\/encoder-pulse-distribution-modules\/\">Richiedi subito un preventivo<\/a>\n    <\/div>\n    <\/div>\n<\/div>\n\n<p>Questo modulo elimina le interferenze degli anelli di massa e consente a un solo encoder di alimentare pi\u00f9 PLC o servoazionamenti senza degradare il segnale.<\/p>\n\n<h2>Messa a terra e disposizione dei cavi corrette<\/h2>\n<p>Anche con hardware avanzato, una messa a terra inadeguata compromette l'affidabilit\u00e0. Collegare sempre le schermature dei cavi <b>solo a un'estremit\u00e0<\/b> (lato PLC) per prevenire gli anelli di massa.<\/p>\n<p><b>Suggerimenti:<\/b><\/p>\n<ul>\n<li>Utilizzate <b>cavi a doppino intrecciato<\/b> per i canali A\/A\u2013, B\/B\u2013, Z\/Z\u2013.<\/li>\n<li>Mantenere i cavi dell'encoder <b>a 10 cm di distanza<\/b> dalle linee di alimentazione del motore.<\/li>\n<li>Utilizzare canalizzazioni metalliche quando si instradano i cavi all'interno dei quadri.<\/li>\n<\/ul>\n\n<h2>Applicazione reale \u2013 Risoluzione della deriva del segnale su una linea di confezionamento<\/h2>\n<p>Una linea di confezionamento alimentare segnalava salti di posizione casuali. L'encoder collegato direttamente al PLC subiva forti EMI dai drive vicini.<\/p>\n<p>Dopo l'installazione di un <strong>modulo di isolamento degli impulsi ABZ AOSI<\/strong> e la sostituzione del cavo con doppini intrecciati schermati, la deriva \u00e8 scomparsa.<\/p>\n<p>\ud83d\udcca <b>Risultati dopo la correzione<\/b><\/p>\n\n<div class=\"aosi-wz-table2\">\n<table class=\"aosi-wz-table1\">\n<tbody>\n<tr>\n<td>\n<b>Parametro<\/b>\n<\/td>\n<td>\n<b>Prima<\/b>\n<\/td>\n<td>\n<b>Dopo<\/b>\n<\/td>\n<\/tr>\n<tr>\n<td>Errore di conteggio<\/td>\n<td>\u00b18 impulsi<\/td>\n<td>0 impulsi<\/td>\n<\/tr>\n<tr>\n<td>Precisione di posizione<\/td>\n<td>\u00b12 mm<\/td>\n<td>\u00b10.3 mm<\/td>\n<\/tr>\n<tr>\n<td>Tempo di inattivit\u00e0\/settimana<\/td>\n<td>4 ore<\/td>\n<td>0 ore<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n\n<p>Dopo l'installazione del <strong>modulo di isolamento differenziale RS422<\/strong>, il feedback dell'encoder \u00e8 diventato completamente stabile \u2014 zero perdita di impulsi anche ad alta velocit\u00e0 del motore.<\/p>\n<p>La precisione di posizionamento \u00e8 migliorata di quasi <b>90%<\/b>, e il sistema ha funzionato in modo continuo senza arresti imprevisti.<\/p>\n<p>Ci\u00f2 dimostra come un modulo di distribuzione degli impulsi dell'encoder con isolamento ottico non solo elimini il rumore EMI, ma migliori anche l'affidabilit\u00e0 complessiva della macchina e l'efficienza produttiva.<\/p>\n\n<h2>Come l'isolamento migliora l'affidabilit\u00e0 a lungo termine<\/h2>\n<p>I moduli di isolamento non solo eliminano le interferenze, ma prolungano anche la vita del sistema:<\/p>\n<ul>\n<li><b>Manutenzione ridotta:<\/b> Un ingresso stabile significa nessun falso trigger.<\/li>\n<li><b>Portata estesa:<\/b> Affidabile fino a 30 metri.<\/li>\n<li><b>Protezione contro le sovratensioni:<\/b> La barriera ottica previene i danni al PLC.<\/li>\n<li><b>Scalabilit\u00e0:<\/b> Collegate pi\u00f9 PLC o azionamenti servo con facilit\u00e0.<\/li>\n<\/ul>\n<p>Questi moduli sono ora standard in <b>sistemi di automazione di fabbrica, robotica e sincronizzazione servo<\/b>, dove ogni impulso conta.<\/p>\n\n<h2>FAQ sul segnale instabile dell'encoder nei sistemi PLC<\/h2>\n<div class=\"aosi-wz-sfqall0723\">\n<button class=\"aosi-wz-sfq0723\">D1: Perch\u00e9 il segnale del mio encoder oscilla in un sistema PLC?<\/button>\n<div class=\"aosi-wz-sfq0723-lb\">\n  <p>R1: Interferenze, loop di terra e lunghe distanze dei cavi sono le cause principali. Il cablaggio differenziale e i moduli di isolamento risolvono efficacemente questi problemi.<\/p>\n<\/div>\n\n<button class=\"aosi-wz-sfq0723\">D2: Come confermare che il rumore \u00e8 la causa degli errori dell'encoder?<\/button>\n<div class=\"aosi-wz-sfq0723-lb\">\n  <p>R2: Utilizzate un oscilloscopio. Bordi d'onda quadra irregolari o salti di impulsi confermano l'interferenza.<\/p>\n<\/div>\n\n<button class=\"aosi-wz-sfq0723\">D3: Gli encoder RS422 sono migliori dei tipi TTL?<\/button>\n<div class=\"aosi-wz-sfq0723-lb\">\n  <p>R3: S\u00ec. I segnali differenziali RS422 annullano l'EMI e supportano distanze dei cavi maggiori con maggiore affidabilit\u00e0.<\/p>\n<\/div>\n\n<button class=\"aosi-wz-sfq0723\">D4: A cosa serve un modulo di distribuzione degli impulsi dell'encoder?<\/button>\n<div class=\"aosi-wz-sfq0723-lb\">\n  <p>R4: Isola e amplifica i segnali dell'encoder per alimentare in sicurezza pi\u00f9 PLC o azionamenti.<\/p>\n<\/div>\n\n<button class=\"aosi-wz-sfq0723\">D5: Come devono essere messi a terra i cavi dell'encoder?<\/button>\n<div class=\"aosi-wz-sfq0723-lb\">\n  <p>R5: Collegate la schermatura a terra solo a un'estremit\u00e0 (lato PLC). Evitate la messa a terra a doppia estremit\u00e0.<\/p>\n<\/div>\n\n<button class=\"aosi-wz-sfq0723\">D6: Un encoder pu\u00f2 collegarsi direttamente a due PLC?<\/button>\n<div class=\"aosi-wz-sfq0723-lb\">\n  <p>R6: Non in modo sicuro. Utilizzate un modulo di isolamento o distribuzione per prevenire riflessioni del segnale e disallineamenti di tensione.<\/p>\n<\/div>\n<\/div>\n\n<h2>Conclusione<\/h2>\n<p><strong>Segnali instabili dell'encoder<\/strong> possono compromettere la precisione dell'automazione \u2014 ma con l'isolamento e un cablaggio corretto, la stabilit\u00e0 \u00e8 facile da ottenere.<br>L'aggiunta di un modulo di distribuzione degli impulsi dell'encoder garantisce un feedback ABZ pulito e privo di interferenze, protegge gli ingressi del PLC e migliora la precisione di controllo.<\/p>\n<p>Per un feedback di movimento ad alta affidabilit\u00e0, esplorate l'intera gamma di <a href=\"https:\/\/aositerminals.com\/it\/product-category\/encoder-pulse-distribution-modules\/\">Moduli di distribuzione degli impulsi dell'encoder AOSI<\/a> \u2014 progettati per applicazioni di automazione, packaging e robotica.<\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"Risolvete i segnali instabili dell'encoder nei PLC. Scoprite le cause, le soluzioni di cablaggio e come i moduli di isolamento AOSI eliminano l'EMI per garantire un feedback preciso degli impulsi.","protected":false},"author":4,"featured_media":36890,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[1],"tags":[],"class_list":["post-36878","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-uncategorized"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v24.7 (Yoast SEO v24.7) - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Why Encoder Signals Become Unstable in PLC Systems (and How to Fix It) - AOSI Terminal Blocks &amp; Module Manufacturer | Industrial Connectivity Solutions<\/title>\n<meta name=\"description\" content=\"Fix unstable encoder signals in PLCs. Learn causes, wiring solutions, and how AOSI isolation modules eliminate EMI to ensure accurate pulse feedback.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/aositerminals.com\/it\/solutions\/unstable-encoder-signal-in-plc\/\" \/>\n<meta property=\"og:locale\" content=\"it_IT\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Why Encoder Signals Become Unstable in PLC Systems (and How to Fix It)\" \/>\n<meta property=\"og:description\" content=\"Fix unstable encoder signals in PLCs. Learn causes, wiring solutions, and how AOSI isolation modules eliminate EMI to ensure accurate pulse feedback.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/aositerminals.com\/it\/solutions\/unstable-encoder-signal-in-plc\/\" \/>\n<meta property=\"og:site_name\" content=\"AOSI Terminal Blocks &amp; Module Manufacturer | Industrial Connectivity Solutions\" \/>\n<meta property=\"article:published_time\" content=\"2025-11-03T01:48:26+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-11-03T07:47:41+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/aositerminals.com\/wp-content\/uploads\/2025\/10\/Why-Encoder-Signals-Become-Unstable-in-PLC-Systems.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"800\" \/>\n\t<meta property=\"og:image:height\" content=\"600\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"liqi001\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Scritto da\" \/>\n\t<meta name=\"twitter:data1\" content=\"liqi001\" \/>\n\t<meta name=\"twitter:label2\" content=\"Tempo di lettura stimato\" \/>\n\t<meta name=\"twitter:data2\" content=\"6 minuti\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/aositerminals.com\/de\/solutions\/unstable-encoder-signal-in-plc\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/aositerminals.com\/de\/solutions\/unstable-encoder-signal-in-plc\/\"},\"author\":{\"name\":\"liqi001\",\"@id\":\"https:\/\/aositerminals.com\/ru\/#\/schema\/person\/ea80420f2fbb21490fba5efdc31bc514\"},\"headline\":\"Why Encoder Signals Become Unstable in PLC Systems (and How to Fix It)\",\"datePublished\":\"2025-11-03T01:48:26+00:00\",\"dateModified\":\"2025-11-03T07:47:41+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/aositerminals.com\/de\/solutions\/unstable-encoder-signal-in-plc\/\"},\"wordCount\":1065,\"publisher\":{\"@id\":\"https:\/\/aositerminals.com\/ru\/#organization\"},\"image\":{\"@id\":\"https:\/\/aositerminals.com\/de\/solutions\/unstable-encoder-signal-in-plc\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/aositerminals.com\/wp-content\/uploads\/2025\/10\/Why-Encoder-Signals-Become-Unstable-in-PLC-Systems.jpg\",\"articleSection\":[\"\u672a\u5206\u7c7b\"],\"inLanguage\":\"it-IT\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/aositerminals.com\/de\/solutions\/unstable-encoder-signal-in-plc\/\",\"url\":\"https:\/\/aositerminals.com\/de\/solutions\/unstable-encoder-signal-in-plc\/\",\"name\":\"Why Encoder Signals Become Unstable in PLC Systems (and How to Fix It) - AOSI Terminal Blocks &amp; Module Manufacturer | Industrial Connectivity Solutions\",\"isPartOf\":{\"@id\":\"https:\/\/aositerminals.com\/ru\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/aositerminals.com\/de\/solutions\/unstable-encoder-signal-in-plc\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/aositerminals.com\/de\/solutions\/unstable-encoder-signal-in-plc\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/aositerminals.com\/wp-content\/uploads\/2025\/10\/Why-Encoder-Signals-Become-Unstable-in-PLC-Systems.jpg\",\"datePublished\":\"2025-11-03T01:48:26+00:00\",\"dateModified\":\"2025-11-03T07:47:41+00:00\",\"description\":\"Fix unstable encoder signals in PLCs. Learn causes, wiring solutions, and how AOSI isolation modules eliminate EMI to ensure accurate pulse feedback.\",\"breadcrumb\":{\"@id\":\"https:\/\/aositerminals.com\/de\/solutions\/unstable-encoder-signal-in-plc\/#breadcrumb\"},\"inLanguage\":\"it-IT\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/aositerminals.com\/de\/solutions\/unstable-encoder-signal-in-plc\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"it-IT\",\"@id\":\"https:\/\/aositerminals.com\/de\/solutions\/unstable-encoder-signal-in-plc\/#primaryimage\",\"url\":\"https:\/\/aositerminals.com\/wp-content\/uploads\/2025\/10\/Why-Encoder-Signals-Become-Unstable-in-PLC-Systems.jpg\",\"contentUrl\":\"https:\/\/aositerminals.com\/wp-content\/uploads\/2025\/10\/Why-Encoder-Signals-Become-Unstable-in-PLC-Systems.jpg\",\"width\":800,\"height\":600,\"caption\":\"unstable encoder signal\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/aositerminals.com\/de\/solutions\/unstable-encoder-signal-in-plc\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"\u9996\u9875\",\"item\":\"https:\/\/aositerminals.com\/en\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Why Encoder Signals Become Unstable in PLC Systems (and How to Fix It)\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/aositerminals.com\/ru\/#website\",\"url\":\"https:\/\/aositerminals.com\/ru\/\",\"name\":\"Industrial Automation Terminal Blocks\",\"description\":\"Factory-direct pluggable, spring &amp; screw terminal blocks and I\/O \/ relay modules. Fast OEM \/ ODM, global shipping.\",\"publisher\":{\"@id\":\"https:\/\/aositerminals.com\/ru\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/aositerminals.com\/ru\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"it-IT\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/aositerminals.com\/ru\/#organization\",\"name\":\"Industrial Automation Terminal Blocks\",\"url\":\"https:\/\/aositerminals.com\/ru\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"it-IT\",\"@id\":\"https:\/\/aositerminals.com\/ru\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/aositerminals.com\/wp-content\/uploads\/2025\/03\/aff0c45cf8d34c8eee2824ecf650eb5.webp\",\"contentUrl\":\"https:\/\/aositerminals.com\/wp-content\/uploads\/2025\/03\/aff0c45cf8d34c8eee2824ecf650eb5.webp\",\"width\":215,\"height\":97,\"caption\":\"Industrial Automation Terminal Blocks\"},\"image\":{\"@id\":\"https:\/\/aositerminals.com\/ru\/#\/schema\/logo\/image\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\/\/aositerminals.com\/ru\/#\/schema\/person\/ea80420f2fbb21490fba5efdc31bc514\",\"name\":\"liqi001\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"it-IT\",\"@id\":\"https:\/\/aositerminals.com\/ru\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/c3bff73b203e4695c70f815f58d8fc65bdd703d79bdd517e01042fd8bee47f1e?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/c3bff73b203e4695c70f815f58d8fc65bdd703d79bdd517e01042fd8bee47f1e?s=96&d=mm&r=g\",\"caption\":\"liqi001\"},\"url\":\"https:\/\/aositerminals.com\/it\/solutions\/author\/liqi001\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Perch\u00e9 i segnali dell'encoder diventano instabili nei sistemi PLC (e come risolverlo) - Produttore di morsettiere e moduli AOSI | Soluzioni di connettivit\u00e0 industriale","description":"Risolvete i segnali instabili dell'encoder nei PLC. Scoprite le cause, le soluzioni di cablaggio e come i moduli di isolamento AOSI eliminano l'EMI per garantire un feedback preciso degli impulsi.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/aositerminals.com\/it\/solutions\/unstable-encoder-signal-in-plc\/","og_locale":"it_IT","og_type":"article","og_title":"Why Encoder Signals Become Unstable in PLC Systems (and How to Fix It)","og_description":"Fix unstable encoder signals in PLCs. Learn causes, wiring solutions, and how AOSI isolation modules eliminate EMI to ensure accurate pulse feedback.","og_url":"https:\/\/aositerminals.com\/it\/solutions\/unstable-encoder-signal-in-plc\/","og_site_name":"AOSI Terminal Blocks &amp; Module Manufacturer | Industrial Connectivity Solutions","article_published_time":"2025-11-03T01:48:26+00:00","article_modified_time":"2025-11-03T07:47:41+00:00","og_image":[{"width":800,"height":600,"url":"https:\/\/aositerminals.com\/wp-content\/uploads\/2025\/10\/Why-Encoder-Signals-Become-Unstable-in-PLC-Systems.jpg","type":"image\/jpeg"}],"author":"liqi001","twitter_card":"summary_large_image","twitter_misc":{"Scritto da":"liqi001","Tempo di lettura stimato":"6 minuti"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/aositerminals.com\/de\/solutions\/unstable-encoder-signal-in-plc\/#article","isPartOf":{"@id":"https:\/\/aositerminals.com\/de\/solutions\/unstable-encoder-signal-in-plc\/"},"author":{"name":"liqi001","@id":"https:\/\/aositerminals.com\/ru\/#\/schema\/person\/ea80420f2fbb21490fba5efdc31bc514"},"headline":"Why Encoder Signals Become Unstable in PLC Systems (and How to Fix It)","datePublished":"2025-11-03T01:48:26+00:00","dateModified":"2025-11-03T07:47:41+00:00","mainEntityOfPage":{"@id":"https:\/\/aositerminals.com\/de\/solutions\/unstable-encoder-signal-in-plc\/"},"wordCount":1065,"publisher":{"@id":"https:\/\/aositerminals.com\/ru\/#organization"},"image":{"@id":"https:\/\/aositerminals.com\/de\/solutions\/unstable-encoder-signal-in-plc\/#primaryimage"},"thumbnailUrl":"https:\/\/aositerminals.com\/wp-content\/uploads\/2025\/10\/Why-Encoder-Signals-Become-Unstable-in-PLC-Systems.jpg","articleSection":["\u672a\u5206\u7c7b"],"inLanguage":"it-IT"},{"@type":"WebPage","@id":"https:\/\/aositerminals.com\/de\/solutions\/unstable-encoder-signal-in-plc\/","url":"https:\/\/aositerminals.com\/de\/solutions\/unstable-encoder-signal-in-plc\/","name":"Perch\u00e9 i segnali dell'encoder diventano instabili nei sistemi PLC (e come risolverlo) - Produttore di morsettiere e moduli AOSI | Soluzioni di connettivit\u00e0 industriale","isPartOf":{"@id":"https:\/\/aositerminals.com\/ru\/#website"},"primaryImageOfPage":{"@id":"https:\/\/aositerminals.com\/de\/solutions\/unstable-encoder-signal-in-plc\/#primaryimage"},"image":{"@id":"https:\/\/aositerminals.com\/de\/solutions\/unstable-encoder-signal-in-plc\/#primaryimage"},"thumbnailUrl":"https:\/\/aositerminals.com\/wp-content\/uploads\/2025\/10\/Why-Encoder-Signals-Become-Unstable-in-PLC-Systems.jpg","datePublished":"2025-11-03T01:48:26+00:00","dateModified":"2025-11-03T07:47:41+00:00","description":"Risolvete i segnali instabili dell'encoder nei PLC. Scoprite le cause, le soluzioni di cablaggio e come i moduli di isolamento AOSI eliminano l'EMI per garantire un feedback preciso degli impulsi.","breadcrumb":{"@id":"https:\/\/aositerminals.com\/de\/solutions\/unstable-encoder-signal-in-plc\/#breadcrumb"},"inLanguage":"it-IT","potentialAction":[{"@type":"ReadAction","target":["https:\/\/aositerminals.com\/de\/solutions\/unstable-encoder-signal-in-plc\/"]}]},{"@type":"ImageObject","inLanguage":"it-IT","@id":"https:\/\/aositerminals.com\/de\/solutions\/unstable-encoder-signal-in-plc\/#primaryimage","url":"https:\/\/aositerminals.com\/wp-content\/uploads\/2025\/10\/Why-Encoder-Signals-Become-Unstable-in-PLC-Systems.jpg","contentUrl":"https:\/\/aositerminals.com\/wp-content\/uploads\/2025\/10\/Why-Encoder-Signals-Become-Unstable-in-PLC-Systems.jpg","width":800,"height":600,"caption":"unstable encoder signal"},{"@type":"BreadcrumbList","@id":"https:\/\/aositerminals.com\/de\/solutions\/unstable-encoder-signal-in-plc\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"\u9996\u9875","item":"https:\/\/aositerminals.com\/en\/"},{"@type":"ListItem","position":2,"name":"Why Encoder Signals Become Unstable in PLC Systems (and How to Fix It)"}]},{"@type":"WebSite","@id":"https:\/\/aositerminals.com\/ru\/#website","url":"https:\/\/aositerminals.com\/ru\/","name":"Morsetti per automazione industriale","description":"Morsettiere a innesto, a molla e a vite e moduli I\/O\/rel\u00e8 diretti in fabbrica. OEM\/ODM veloce, spedizione globale.","publisher":{"@id":"https:\/\/aositerminals.com\/ru\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/aositerminals.com\/ru\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"it-IT"},{"@type":"Organization","@id":"https:\/\/aositerminals.com\/ru\/#organization","name":"Morsetti per automazione industriale","url":"https:\/\/aositerminals.com\/ru\/","logo":{"@type":"ImageObject","inLanguage":"it-IT","@id":"https:\/\/aositerminals.com\/ru\/#\/schema\/logo\/image\/","url":"https:\/\/aositerminals.com\/wp-content\/uploads\/2025\/03\/aff0c45cf8d34c8eee2824ecf650eb5.webp","contentUrl":"https:\/\/aositerminals.com\/wp-content\/uploads\/2025\/03\/aff0c45cf8d34c8eee2824ecf650eb5.webp","width":215,"height":97,"caption":"Industrial Automation Terminal Blocks"},"image":{"@id":"https:\/\/aositerminals.com\/ru\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/aositerminals.com\/ru\/#\/schema\/person\/ea80420f2fbb21490fba5efdc31bc514","name":"liqi001","image":{"@type":"ImageObject","inLanguage":"it-IT","@id":"https:\/\/aositerminals.com\/ru\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/c3bff73b203e4695c70f815f58d8fc65bdd703d79bdd517e01042fd8bee47f1e?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/c3bff73b203e4695c70f815f58d8fc65bdd703d79bdd517e01042fd8bee47f1e?s=96&d=mm&r=g","caption":"liqi001"},"url":"https:\/\/aositerminals.com\/it\/solutions\/author\/liqi001\/"}]}},"_links":{"self":[{"href":"https:\/\/aositerminals.com\/it\/wp-json\/wp\/v2\/posts\/36878","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/aositerminals.com\/it\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/aositerminals.com\/it\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/aositerminals.com\/it\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/aositerminals.com\/it\/wp-json\/wp\/v2\/comments?post=36878"}],"version-history":[{"count":9,"href":"https:\/\/aositerminals.com\/it\/wp-json\/wp\/v2\/posts\/36878\/revisions"}],"predecessor-version":[{"id":36954,"href":"https:\/\/aositerminals.com\/it\/wp-json\/wp\/v2\/posts\/36878\/revisions\/36954"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/aositerminals.com\/it\/wp-json\/wp\/v2\/media\/36890"}],"wp:attachment":[{"href":"https:\/\/aositerminals.com\/it\/wp-json\/wp\/v2\/media?parent=36878"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/aositerminals.com\/it\/wp-json\/wp\/v2\/categories?post=36878"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/aositerminals.com\/it\/wp-json\/wp\/v2\/tags?post=36878"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}